Ceiling Mounted ERV

FEATURES
-
ABS encapsulated DC motor, 10 speeds
-
Primary washable filter (MERV6), MERV13 optional
-
Flexible installation: suspended x wall mounted
-
Wireless timer - 4 speeds 15/30/45 minutes
-
Enthalpic energy exchange core
-
Casing made with galvanized steel sheet, rust-proof
-
EPP foam insulation
-
No drain
-
Auto-defrosting function
-
Perfect for commercial and residential spaces

SPECIFICATIONS

WARRANTY: Our devices carry a 5-year ERV core warranty and a 5-year parts replacement warranty. All our devices comply with CSA standards.
TECHNICAL DOCUMENTS
LCD WIRED CONTROLLER

-
Heat Recovery Mode
-
Auto Mode
-
Bypass Mode
-
Sleep Mode
And advanced functions as:
-
Low temperature operation
-
Intelligent airflow compensation
FLEXIBLE INSTALLATION
• Suspended x wall mounted
• Parallel airflow
• Available with inverted installation
• Reserved side ports for OA and EA

-
OA: Outdoor Air
-
EA: Exhaust Air
-
RA: Return Air
-
SA: Supply Air
DESIGN


DIMENSIONS

Unit: in

HOW TO SELECT THE RIGHT MODEL
The ASHRAE 62.2 standard defines the minimum ventilation rates required for residential buildings. The formula for calculating the minimum airow rate (in cubic feet per minute, CFM) is:
CFM = 0.01 x floor area (sq.ft) + 7.5 x (no. of bedrooms + 1)
For example, if you have a 2,000 square foot home with 3 bedrooms:
CFM = 0.01 x 2,000 + 7.5 x (3 + 1)
CFM = 20 + 30 = 50 CFM
ASHRAE 62.2-2010
Required Continuous Ventilation Rate (CFM)

* Based on the 2010 ASHRAE 62.2 standard